Heat Pump Specifications (RS-HT Series)
| Parameter |
Unit |
RS-HT-38U |
RS-HT-58V |
RS-HT-70V |
RS-HT-115V |
| Heating Capacity |
kW |
36.8 |
57.2 |
69.8 |
114.4 |
| COP |
— |
4 |
4.2 |
4.1 |
4.2 |
| Power Supply |
— |
colspan=4 → 380~415V / 50Hz / 3Ph |
| Input Power |
kW |
9.2 |
13.6 |
17 |
27.2 |
| Rated Current |
A |
23.6 |
34.8 |
42.4 |
69.6 |
| Rated Water Temperature |
°C |
colspan=4 → 75 |
| Max Water Temperature |
°C |
colspan=4 → 80 |
| Heat Exchanger (Condenser) |
— |
colspan=4 → Brazed Plate Heat Exchanger / Tube in Shell |
| Evaporator |
— |
colspan=4 → Blue Finned Evaporator Coil |
| Throttling Valve |
— |
colspan=4 → Electronic Expansion Valve |
| Refrigerant |
— |
colspan=4 → R134a |
| Compressor |
— |
colspan=4 → Scroll (Copeland / Panasonic / Sunniva) |
| Number of Compressor |
— |
2 |
2 |
2 |
4 |
| Fan Quantity |
Piece |
2 |
2 |
2 |
4 |
| Rated Hot Water Output @ 60°C |
LPH |
1060 |
1640 |
2000 |
3280 |
| Rated Hot Water Output @ 70°C |
LPH |
750 |
1160 |
1400 |
2310 |
| Rated Hot Water Output @ 80°C |
LPH |
560 |
870 |
1060 |
1740 |
| Water Flow |
m³/hr |
6.6 |
10 |
12.2 |
20 |
| Water Pressure Drop |
kPa |
≤58 |
≤65 |
≤70 |
≤75 |
| Weight |
kg |
375 |
510 |
610 |
1040 |
| Noise at 1 Meter |
dB(A) |
≤74 |
≤76 |
≤78 |
≤81 |
| Pipe Size |
inch |
R1-1/2 |
R1-1/2 |
R2 |
R2-1/2 |
| Dimension |
mm |
1600×990×1150 |
1850×950×1635 |
1850×950×1635 |
2200×2100×1800 |
Testing Condition: Ambient Temp. (DB/WB)=20°C/15°C, Inlet Water Temp. = 55°C, Outlet Water Temp. = 60°C
(Ε.Τ. 10°C./ С.Т. 65°C)